21. What is the purpose of taking Capacitance and Tan Delta
Test in
Transformer bushing?
22. What are the protections to be used for Generator?
23. Draw the vector diagram and condition for the
following: 1) Dyn1
2) Ynd0 3) YnYn0
24. What happens when the polarity changes in CT? Explain
briefly?
25. Explain the Term in CT Name Plate – Class: 5P10
Answer Posted / naresh
Pole slipping,backup protection,differential,dead machine
protection,low forward power,voltage control over
current,current control over voltage,df/dt,if ct polarity
chenge in protection reverse active power flows to relay
and diff current flow and in metering import power wil show
in energy meter,for five times of primary current 10%
composite error.
| Is This Answer Correct ? | 0 Yes | 7 No |
Post New Answer View All Answers
can any one tell in easy method for circulating current ??
tell me about eletrical contractor
Is a 300w induction motor used in a food processor as powerful as a 1000w DC motor.
how we can come to know that motor winding resistance which showing by DMM is right or wrong???is there any chart or something that we will compare & check???
How much load can be taken for chiller from 1500 kva transformer
what is mean by drives?
High voltage test procedure of in swgr board. why should measure millivolt drop on testing time?
define the active power?
Give some differences between open loop and closed loop control systems.
Write a note on materials used as a fuse element.
which motor have relatively high power factor and what is reason for have high pf? 1.capacitor run motor 2.shaded pole motor 3.capacitor start motor 4.split phase motor
In india, according to trade theory above 5 HP motor reqired star delta starter. But we R connect 11 KV motor with 14MW in Direct to line ( With VCB starter combination) Can U Guess, How it is possible ?????
following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?
What is inverse definite minimum time lag relay? Where is it use?
In case of salient pole alternator when number of poles are 4 or more than 4 it helps the flux wave to be sinusoid as air gap length is increased from center to tip , but if the number of poles are 2 how does the flux wave is sinusoidal?