What is the basic difference between synchronous machine
and induction machiine?
Answer Posted / iamdon
The differences can be outlines as follows:
1)The synchronous machine runs at synchronous speed at
steady condition(It oscillates during transients which
finally settle down) which is fixed for a particular
machine.The induction machies always runs at speed lower
then synchronous speed.
2)In synchronous machines field winding(generally placed on
rotor)carry DC.Where as in case of Induction machines rotor
winding carry AC.
3)In case of synchronous machines field winding is suplied
from external source where as in case of Induction machines
current is induced in rotor conductor by induction process
(Thats why it is called induction machine).
Author:arbelectbit@yahoo.com
| Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
The electromagnetic torque developed is proportional to what in a D.C series motor?
What is the breaking capacity of transformer and how can we calculate the breaking capacity of tranformer
How Can You Relate Power Engineering With Electrical Engineering?
upto how much low RPM we will run the commercial motor which is run through VFD without any problem occurs in motor.Motor rating Duty is S1 & RPM is 1400.
How many VSC based HVDC are there in India and the world
how to select the no. of brushes in a lap winding?
What is cable tray, its type, and its support?
draw the restricted earth fault protection circuit install on power transformer and identify its parameters and draw C/C curve of it
During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.
what is earthing transformer? draw the winding dia.of earthing transformer.
How will polarity test of Dy5 Transformer ?
why we are not giving the zone 1 trip command to the master trip relay
1.why should we connect the measuring instruments in l.v side in short circuit test of a transformer? 2.why the power factor is less in open circuit test of a transformer?
there is an alternator 480 k.w, 400v,50hz, 4-wire running on load having leakage alternator body earthed current 38 A. is it within acceptable limit? if yes then give reference if no then how to bring within specified limit
why does make gain margin and phase margin on same plot.?