Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What will happen if we give transformer a dc not ac

Answer Posted / aravind

if current is very high it may burn out the windings
but if current is low then primary winding acts as an inductor

Is This Answer Correct ?    4 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how can motor both beasrings insulation resistance can be check?

2078


3 phase induction motor connection star or delta while using ac drive motor is .75 to 5.5 kw

2021


what is 30-phase of transformer

2362


What is a differential amplifier? Also, explain cmrr.

1424


Capacitor is load free component but why ampere meter shows current when capacitor bank breaker close?

1242


Starting times for soft starter & power factor is thier any standard or datas available in manufactures list. Kindly suggest.

1976


Assuming that a dedicated neutral earthing transformer is provided for each GT generator, when the two generators are running in parallel, has consideration been given that the earth fault current from one generator stator winding be split between the two neutral earthing transformers? If so, what adverse impact will this have on the operation of the 59N and 27TN devices?

1714


Diagram and details of polarity test for Current Transformer 11kv 400/200/100/1A

3094


A mass of 1200g is accelerated at 200 cm/s2by a force. The value of the force required is:(a) 2.4N(b) 2400N(c) 240 kN(d) 0.24N

3057


What will be electrical cost per sqft for IT building (basebuild and fitout)and for residential township?

1990


if we install two earth pits with a clear space of 5m without any interconnection,by checking the digital multimeter will it show continuity between earth pits? If so what would be the approx. value

1996


What is earth system using on the floater TN-S or TT. Iam not sure and what ICCP

1791


How will A Medium voltage circuit breaker(11 kV voltage level) operate under short circuit fault condition whether It is having short circuit release like Low voltage circuit breaker or relay should be given?

1996


How I calculate the ELCB for circuit breakers?

2234


I want single line diagram for AMF & DG syncronizing panel

7257