Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

In a Synchronous generator, Can AC voltage be used instead
of DC voltage in field winding of rotor to produce AC power?

Answer Posted / iamdon

No.....AC voltage cannt be used in field winding of rotor
of synchronous machines for following reasons....

1)AC produce poles on rotor whose strength is varying
sinusoidally.It is undesirable because the magnetic locking
between two fields in this case are not achieved troughout
the cycle.At current zero of AC there is no locking at
all.So synchronism will be lost.

2)Field winding is designed for DC. It has higher
resistance.According to Lenz law emf is induced in field
winding.so current flowing through through winding will be
very low.Pole strength is very weak.

Is This Answer Correct ?    30 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What was your role in the silicon evaluation/product ramp? What tools did you use?

1927


Draw a 230kv two-bus bar system showing the following. 1.Two generators (150MW) each connected through one 15.75/230KV transformers 2. 1 outgoing lines 3. Two 230/130 KV transformers 4. BUS PT's 5. CT

2557


how to changeover ups in this power failur time?

1949


state the working principle of incondenscent tube?

1905


Why frame of the motor is specified?. If we mention KW and voltage level,automatically frame is decided or separately frame is compulsory to mention?.

1704


Q.1:What protection will be used on HT and LT side of 33/0.4 KV, MVA transformer. Indicate capacities of protective device to be used. Q.2:Which types of back-up protections are used in the power transformers? What do you understand by the term over travel in the relay? Q.3:How star and delta connected winding transformer are provided from earth fault

2087


Terminal blocks is used for segregate the connections... There is any principle for terminal block..?

2080


defination of transistor controlled series capacitor

2603


is it possible to say motor horsepower number without seeing name plate(when name plate damaged)

5251


why does make gain margin and phase margin on same plot.?

2052


Explain what is clipper and clamper circuits?

1125


Apparent power is expressed as V * I(Conjugate). Why not in V * I ?

3874


8. A DYNAMOMETER TYPE WATTMETER RESPONDS TO THE.......

9213


what is the minimum pay scale for electrical engineer (building construction)in kuwait? plz revert back with yrs of experience & pay scale respectively.

2124


why high speed tripping relay will be used in tripping circuit why not normal relay

1316