Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What are the differents between Breaker & Contactor?

Answer Posted / nishad

Above answer is almost ok. How ever I just add a little
with that.

Basic difference between circuit breaker and contractor is
That, A circuit breaker can make, break and carry current
in all conditions i.e normal, overload and short circuit.
It will protect the system from over load, Earth fault &
unbalance as well as it has different load & trip setting
and it don’t want any fuse back up. That was not inbuilt in
contactor. A contractor can make, break and carry only in
normal and overloaded condition not in short circuit
condition. Also, Contractor are always backup by HRC fuse
where as there is no need of any backup in circuit breaker.
For frequent operation, contractor is more efficient than
the Circuit breaker.

Is This Answer Correct ?    24 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Explain Even and Odd signals?

1906


is it possible to test of bus bar in high rise building without completed full floor ?

1690


How earthing/grounding done in aeroplanes and ships.

3619


What does Bode plot tell you?

1394


Why can't we parallel Voltage transformer secondary circuits?

1635


In TNC switch, is there any 1NO+1NC block ? and if we move over closing position, is ther any affect on trip position or vice versa?

2241


what are the assumptions made in swineburne's test?

2170


What are the insulation standerds for eg H clase and how many insulation standerds are there and its standerds??????

1956


sir i have cleared the apti test of EIL held on 15th march and my interview will be in new delhi on 2nd june.i will be very much helpful if u help me regarding the type of interview questions comes at EIL.(URGENT.........PLZZZZZZZZZZ...............)

2054


I want formula to calculate current loss with distance in km.I searched many sites but didn't right answer.Plz reply me

2064


What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works?

1991


What is the importance of counter based plan & how is it scheduled?

2010


What is effect of over voltage and under voltage on ACB

1972


why don't we use the generator as a motor? and what will happen?

1883


Draw a 230kv two-bus bar system showing the following. 1.Two generators (150MW) each connected through one 15.75/230KV transformers 2. 1 outgoing lines 3. Two 230/130 KV transformers 4. BUS PT's 5. CT

2586