Answer Posted / senthil
instrumentation is a branch of engineering which is used to
control and measure the process variables like
pressure,flow,temp,level.
| Is This Answer Correct ? | 27 Yes | 2 No |
Post New Answer View All Answers
Hi i m B.E. In elect. & comm. I m workin in bio mass plant from 6 mnths as inst. Engg. but now i m in dept. Of operation as shift engg...which is best operation or inst. 4 me? M confusd..plz help and reply me..
how can be calibrate flow indication transmitter (rosemount) it shows excess milli amps nearly about 24 ma on full scale, but its scale was set on 20ma on full scale..???how can be simiulate..???
Describe how to use megger to measure the earth resistance and insulation resistance
What is super thermocoupal?
How to Calibrate Ultrasonic flow Transmitter in Field
what is droop in governer ,type of droop ,how it work
Can I route 110 VDC and 24 VDC in a same Duct for our Interposing relay cabinet? IF yes or NO Please provide me IEEE Std. for the same. Please i required it on Urgent basis, i need to design IRP Cabinets and we have MCC 110VDC and Our Coil side is 24VDC, Please help as soon as possible.
what is the calibration procedure for transweigh make weigh feeder?
What should be the main consideration while starting the Rotating compressor when we dont know the cut in and the cut off pressure setting of the pressure switch
what is a vortex flow meter,mass flow meter and electromagnetic flow meter.particular use of this.means in which condition particular meter is used.
how many types of viberation transmitter and how to calibrate and where use of vibration transmitter
why we use 3 wire rtd direct wiring for temperature measurement instead of temperature transmitter like bearing temperature
We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.
What is difference between ESD and PLC please Explain me clearly.
Why rdt and thermocouple both give different output .and one things more, how to generate ohm or mili volt plz mail me merajalam143545@yahoo.com