Do you know how to maintain a generator, if so what are
those maintenances?
Answer Posted / nabil
Inspection of AC Exciter
Removal of Rotor
(1) Inspection of Stator winding, Stator Wedge Looseness
(2) Inspection of Stator Core
(3) Inspection of Shaft Journal and Shaft Corner by Visual
Inspection, Ultrasonic Examination, Magnetic Particle
Examination
(4) Inspection of Retaining Ring Outer Surface by Ultrasonic
Examination, Penetrate Examination, Visual Inspection
(5) Inspection of End winding
(6) Inspection of Collector Ring, Measuring of Collector
Ring
Groove Depth
(7) Inspection of Rotor Fan and Bolts, Coupling Bolts by
Visual
Inspection, Penetrate Examination, Ultrasonic
Examination
(8) Inspection of Field End winding
(Special) Inspection of AC Exciter
Carrying Rotor into Work Shop and Disassembly of
Retaining Rings
The difference from the 4th year inspection are below.
(1) Inspection of Each Wedge by Fluorescent Penetrant
Examination, Magnetic Particle Examination
(2) Inspection of Retaining Ring Inner Surface by
Ultrasonic Examination, Visual Inspection, Penetrant
Examination
(3) Inspection of Winding in the Slot Section
(4) Replacement of Pole to Pole Connector
(5) Inspection of Main Lead and Insulation cover Inspection
of Bolts by Ultrasonic Examination, Magnetic Particle
Examination
(6) Measuring of Inter Turn Voltage, High Potential Test,
Measuring of Winding Resistance
(7) Inspection of Coupling by Visual Inspection, Ultrasonic
Examination, Penetrant Examination
Overall Inspection for Stator Winding
Removal of Rotor
(1) Inspection of Stator Wedge Looseness
(2) Inspection of Spacer inside Stator Slot Section
(3) Inspection of Bolts for Endwinding Portion, Looseness
of Endwinding Tie, Looseness of Phase Connection Ring etc.
(4) Inspection of Sliding Structure (Water Cooled Stator
Winding)
- Periodical inspection, every month
the carbon brush length, cleaning the brush holder one
by one
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
Why synchronous motor is used in power factor improvement,dc series in lift
what is the electrical?
Is there a possibility to use such a treshold voltage for the NMOS part of a CMOS circuit that during the switching it will start conducting only after the PMOS part will be already closed, by this eliminating the leakedge current? Please note, I'm not asking about the well bias in standby mode, but about the "antileakedge" measures during normal operation.
We have 250 KW x 2 motors, which are load from 25% to 100% varying load in every minute , so how can we compansate the power factor. pl give your opinions on the above subject.
What is the de rating factor of cable? What is the importance of the de rating factor in cable select
If symmetrical fault occurs at the terminal of a synchronous motor then how the motor will act...explain it..
what is the use of the circle diagram
How a band pass filter is constructed?
How to discuss the phase shift of transformer considering open delta?
What happens if we connect a single phase energy meter in reverse polarity.
why do we lay up the core of a cable?
If Dg set load increase 25%, How much increase fuel Consumption (15 kva 2 cylinder DG set)
What is meant by analogous system?
why transmission is only 3 phase and not 2 or 4 or poly phases
Explain about technical and non technical losses in distribution system?