how to check the earth resistance value& what is the
minimum earth resistance for good earthing sysytem.
Answer Posted / ramaraj.g
The earth resistance value can be checked by the use of
earth resistance tester (called megger earth tester). The
best earth resistance should be less than one ohm but the
permissible value is less than 5 ohm. For rocky areas it
should be less than 5 ohms.
we using the DMM in check the L - N , N- E ,E- L
this small calc
L-N - 230 v
N-E - BELLOW THE 2 VOLTS IS GOOD ERATH CONN
E-L - 230v IS RECONFORM TO GOOD EARTH OR NOT
L-N = E-L
| Is This Answer Correct ? | 77 Yes | 11 No |
Post New Answer View All Answers
XYZ
What current position are you holding in your current company?
if any body have question paper of railway (section engineering),then plz send me .i will thank of him/her.
I am apply the AAI. So i want electrical sample question paper in technical with answer my id is vijayjobsmart@gmail.com
Dear All we are having a problem in G120 BOP showing alarm A0503, F0052, F0060 we can not remove fault alarm ,Please any body help us. kowsar
If a current -8+6sin6t is flowing three ammeter, one is a centre zero PMMC meter, one is true rms meter and one is moving iron meter. What are the reading of these three meter respectively?
Is it possible to measure correct value of earth resistance & cable insulation ristance with out disconncting earth lead & both sides of cable ends? If not, any other method to measure ER & CIR with out disconneting from the system.
sir& friends i want the collection of recent quetions asked in interview of top most companies please send me on my email san.jsr@hotmail.com
TO CALCULATE THE RESISTANCE OF GRR OF HT MOTOR 400KW WHEREAS STATOR VOLTAGE 6.6KV AND ROTOR VOLTAGE 705V AND ROTOR CURRENT IS 346A.
plese send me the oces/dgfs sylabus and previous year question pattern of electrical engg.?
i m in need of current rating chart of heavy duty pvc/xlpe, cu/al cables. can somebody provide me? if yes, plz send me at ashish_patel111@yahoo.com
Draw the vector diagram and condition for the following: 1) Dyn1 2) Ynd0 3) YnYn0
I HAVE BEEN SELECTED FOR APGENCO A.E(ELECTRICAL) 2008.HOW MUCH WEIGHTAGE FOR INTERVIEW AND WRITTEN TEST.HOW I HAVE TO PREPARE. PLEASE GIVE INFORMATION IF U KNOW.WHAT ABT G.D THIS TIME.CALL RATIO 1:2
please send 5yearje solved papers on my email himmatsinghnathawat@gmail.com
Q.1:What protection will be used on HT and LT side of 33/0.4 KV, MVA transformer. Indicate capacities of protective device to be used. Q.2:Which types of back-up protections are used in the power transformers? What do you understand by the term over travel in the relay? Q.3:How star and delta connected winding transformer are provided from earth fault