Name different types of circuit breakers and their voltage
ratings?
Answer Posted / magendra
1.oil cb(3.3kv-220kv)
2.air blast cb(66-1100kv)
sf6 cb(3.3-765kv)
vaccume cb(3.3-33kv)
| Is This Answer Correct ? | 6 Yes | 15 No |
Post New Answer View All Answers
TCS IS IT COMPANY THEN WHY DO THEY NEED ELECTRICAL &ELECTRONICS ENGINEERS?
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.
what is the IPC ? & what the uses ?
what is the function of capacitor duty contactor in an capacitor panel???
why they were using TRIAC instead relay in some controllers and what is the advantages.
what is x'mer ,isolation x'mer & yltra-isolation x'mer?????
how copper and aluminium wires or cables are choose for current rating? please provide copper and aluminium wire selection chart for different current rating ?
What is Icu and Ics and what is difference b/w them. please tell me how to calculate a size of a copper bar for a system or a breaker... reply on... king.arish@gmail.com would be waiting for a logical answer.
11000volt DG set carnt kaise banvay
how was your last weekend.
what happens if dc supply is given and the remedies for it.
WHAT IS START TO INDUCTION MOTER IN STAR TO DELTA OF >5HP ?
How many lightning arrestors to be installed on 50MX60MX10M building and is there any formular for that?
Power factor =1.000 at factory in supply. However, PF = 0.8 at motor end. Current = 100 Amp, Voltage = 400 V. What is the power distribution loss? Can I reduce it by adding capacitor at the load feeder?
What is difference between Sample test and Routine test in safety standard?