What is the difference between EARTH & NEUTRAL?
Answer Posted / adhiraj thiagarajan
The earth pin is larger than the phase & neutral pins since
the earth should be first connected when plug is inserted
into power socket and the last to come out when plug is
removed from power socket
| Is This Answer Correct ? | 1 Yes | 3 No |
Post New Answer View All Answers
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.
how much flux density of CRNO core
when 20hp 3 phase motor start no load condition in star or delta connection.find current and write formula.(tariq)
Hello Friends, How can we recognize the CT Star Point is S1 or S2 in case of Electro Mechanical Relays and what is meant by Restraining coil in relays and what is the purpose of that.. thank you in advance..
HI SIR, AM PREPARING FOR RRB FOR SECTION ENGINEER POST. PLZ SEND ME THE PREVIOUS QUESTION PAPERS AND HELP ME. I HAVE NO ENOUGH TIME MY EXAM DATE IS 22ND JUNE.... MY EMAIL ID IS nalla.amarnath@gmail.com
What is the effect on 3phase induction motor if current setting knob of DOL kept at minimum current?
how to calculate the change over time for star delta starter for different KW motor?
how much value of resistance should connect to 15 kw, 6 pole 3 phase slip ring induction motor having RV-240, RA-42.
What is inrush current? how can calculateit? what is the affect of it?
In an ACB shunt trip coil and undervoltage coil operated normally( breaker open and charged). But closing coil not operating untill manually discharge and recharging. Any help.
if we install two earth pits with a clear space of 5m without any interconnection,by checking the digital multimeter will it show continuity between earth pits? If so what would be the approx. value
What about electrical Units. discrive in detail
What consists of 2 or more thermocouples to be connented series?
i ha done my 10th with 71% ,ITI with 81% 11th with 75% 12th 43% apprentiship with 71% in SAT i secure 1390 ,TOEFL 27 i was refused four times and in all me interview visa officar told that i am not Qualify for study in USA but i completed my 12th yes i got low persentage in my 12th but i seen to much student they already got visa with them 3 or 4 backlocs so why they are refused me ?
by what factor the starting current is used when comparing star and delta connection for motor starting?