what should be the value of proper neutral earthing
resistance?
Answer Posted / mahesh sali
for solid earthing it will come around - 5 ohms
for resistive earthing the value being 1 to 2 ohms
for reactance earthing the above value will come down
around , it will be les than 1 ohm ,
thank u
| Is This Answer Correct ? | 6 Yes | 0 No |
Post New Answer View All Answers
if there are six generators (3 gas CATT, one Jenbacher o1 MW each, and two nos Diesel 01 no 01 mw other 0.65mw EDGs ( say), 3 CAtt gas set have identical pole pitch,01mw EDG and Jenbacher gas Set have different pole pitch, how their power connection can be done to connect a common bus bar during installation. in short, how different pole pitched generators power connection can be done to connect a common busbar system through generators incomer ACBs.
howmany electrician should maintain for a 1000 kva used plant... in kerala..
how electical engineer is related to apsrtc (general) post? if they ask a question in interview as why did u choose this job what shd be answer
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
what is basic difference betmeen normal & flame proof motor??
Explain in details how you would react to an unexpected incident when your supervisor or manager is not around to give instructions?
Pls tell me whether we can use EN3A material for shafts of Permanent magnet alternator.What will be the effect of magnetic and nonmagnetic material for shafts on magnetic properties of PM rotor .
Why the earth to phase voltage is high 250 compare to other two phases
Please provided formula for calculate the cable size from step up transformer to M.V panel, run overhead aluminum cables, total load is 5mega watt, total length 900 feet.
1.What is captive power plant? 2.What is national grid?Give brief idea.
TELL ME WHAT IS INDUCTOR AND CAPACITOR WHAT IS IT BASIC OPERATION ANDFUNCTION?
is this the formula of building wiring to get the main breaker.Watts/volts*.8%+higher motor*(25%)=ampere. yes or no or send the correct formula for building wiring.
In siemens S7-300 PLC, what is function and function block ? What is the difference between them ? When to use function and when to use function block ?
how you will decide the distance between the power transformer and its fencing
the grid connection required for a 50 MegaWatt fotovoltaic powerplant is higher or lower than 35kv (high or medium tension)?