Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

WHY DG are rated in KVA or MVA ???., but ALL power plants
are rated in KW or MW.,,?

Answer Posted / vithal k.

Power plant capacity is in MW means ultimately its in terms
of Amps, current and in PF.

Whereas DG is there in KVA means in terms of voltage and
current.

PP is directly connected to Grid and hence directly come in
to the picture with System inductance.. where as DG will
have bounded load and no more Inductive load is there
compared to Grid and hence negligibly considered as 1 (PF=1)

Ultimately in KW terms PF came out of picture and hence DG
rating ar3e normally in KVA.

Is This Answer Correct ?    13 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Hi Suppose we have a wye/wye transformer which is grounded at both sides,in this situation, do we have ay ground transformer? in other words, ground transformer can do any thing more (while we have nuetral wire in both sides)? As the last question, what about 3rd harmonic? we have two choices: first using wye/delta transformer + ground transformer and second using wye/wye earthed connection.in the former choice, we dont have 3rd harmoonic at the secondary side but what about Yn/yn conection? do we suffer from 3rd harmonic in the Yn/yn connection?

1964


i ha done my 10th with 71% ,ITI with 81% 11th with 75% 12th 43% apprentiship with 71% in SAT i secure 1390 ,TOEFL 27 i was refused four times and in all me interview visa officar told that i am not Qualify for study in USA but i completed my 12th yes i got low persentage in my 12th but i seen to much student they already got visa with them 3 or 4 backlocs so why they are refused me ?

3426


would the same effect be achieved by reversing the connection to one winding of the induction motor 3-phase?

1801


Where is servomechanism used?

1200


Name the test signals used in control system

1284


What is negative sequence over voltage element?

1963


a 100mva,400/200v transformer has leakage impdce of 10% draws a steady state line currentof---------------

1905


how many single tension hardware are required on a double circuit transmission tower?

1929


Either It Possible a dc Motor to Run On Ac Drive [ Ex : ACS 800 , Yaskawa F7 ] If it is Possible How Pls Inform Me dinesh_elect_eng@yahoo.com

1961


I want to replace the 3 KW DC motor with AC motor so what should be the rating of AC motor? Details Of DC motor to be changed with AC are - Kw - 3, Vf - 310, If - 0.15, Va - 400, Ia - 13, RPM - 2400

1808


What is cut-off rate?

1214


what is parellel power factor correction?

4381


Why is the starting current high in dc motor?

1121


Define open loop control system.

1096


AL=0B9H,bl=75H, ADD AL,BL AL=____________? CF________? OF___________?

2665