Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why rotor current reading is taken & why not stator?

Answer Posted / guest

when supply is given to stator then flux is induced in the
stator & it varies if current is increase

Is This Answer Correct ?    1 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

is that a problem if i connect a single phase load to a secondry delta connected transformer but i get a neutral from other transformer i the system?

1787


If the Brush of DC motor is shifted by 90 deg, then what happens to voltage and torque? Both voltage and torque are zero. how to justify the answer?

1378


What is critical disruptive voltage?

1266


how can I calculate charging current of cable/overhead conductor? what is roll of voltage in it ?

3612


mostly the questions were from machines... d.c. machines, transformer, synchronous and induction all theory paper........ few from power system... but the level of paper was easy.....

1897


Please explain me about Relay curves and their sources to read ?

1755


Is it required to lay 2 runs of GI wires along with armoured cables from one power DB to another Power DB?

1885


how to increase or decrease speed in DC shunt motor by DC convertor

2230


Define super node?

1143


What is main cause of cable's terminal point burned in Lug on high temperature although lug and cable selection is ok as per stantard and also tightness is ok as per situation. so please take in deep and tell correct answer thanku.

8165


What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.

2655


in Contactor opearation Why there is a difference in the values of the operate and release voltage in case AC supply

2040


Efficient electrical earthing in hard rock area

1505


how do we calculate length of starting time and repeated starting of a direct online starter?

1929


In ht capacitor ckt we are using LBS Panel it having isolator with fuse, one of HT fuse flash over, so what is reason behind this event.

2033