State the difference between Surge Arrester and Lightning
arrester,Both are same or not?
Answer Posted / priyanka dhar
Lightning arresters are installed inside the distribution
board and they protect against surge volatges in case of
direct lightning strikes.
surge arresters are installed in sub-distribution board as
well as in terminal equipment thus protecting against surge
voltages due to distant lightning and due to internal
switching operations respectively.
| Is This Answer Correct ? | 3 Yes | 13 No |
Post New Answer View All Answers
in the directional overcurrent and earthfault protection,normally we are setting the angle 45 deg lead for phase fault overcurrent and -45 deg lead for earthfault fro forward direction.but both the fault are operating on the same angle region only.why?how the relay will response?
What are m circles?
temp of cast resin 1500kva tx formerwent up to 138.c but came down very fast to about 100.c within 20 mins when load was reduced from 70% to 60%
how to find 5 kilo meter long under ground 33 kv cable fault location if IR VALUE shows 0.05 M ohm @5000 volt.and cable fault locator shows some time fault distance 3 kilo meter ,3.7 kilo meter and some time 1 kilo meter? now how to find the fault location that where is leakage. note--it is tested with 5000 kv megger and insulation resistance is 0.05 M ohm. and some time 0.03 M ohm comes.
checking procedure of capacitor based motors.used in fans etc?
What do you mean by reach and reach the point of the relay?
i need mat lab program to find out the transmission line losses,regulation and losses
what is the breaking capacity and making capacity of circuit breaker and how
In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.
ANY ONE TELL ME ABOUT generator synchronization panel panel to synchronise 3 gen of 250kva both automatic and manual. 2 gen output vol 415 3ph, 1 gen output vol 400 3ph SEND THE DETAILS DIAGRAM ON THIS EMAIL ADDRESS ayazleo@hotmail.com as soon as possilble best ragrds electrical engineer ayaz mahmood SAUDI TECH
How does cost of generation from hydropower plant compare with other sources of electricity?
Why synchronous motor is used in power factor improvement,dc series in lift
Fantio of tranformer
What is the application of Dyn1 and Dyn11 vector group of transformer?
Post possible questions for Power Factor Panel FAT / SAT