Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how winding temperature detects in power transformer...?

Answer Posted / ullas

a special CT(current transformer ) is used to measure the
winding temperature in a power transformer.
the method is very simple, there will be one winding
temperature measurement pocket in the transformer. in this
a temperature measurement device is dipped and this pocket
will be filled with transformer oil. this special CT will
give output in the form of current which is proportional to
the temperature.
i think this makes a clear picture.

Is This Answer Correct ?    23 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

2158


Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.

2132


What happens if we connect a single phase energy meter in reverse polarity.

2369


What is the difference between electronic regulator and ordinary electrical rheostat regulator for fans?

1109


Explain the different regions in frequency response?

1086


PLS SEND THE RRB CHENNAI MODEL QUESTION PAPER my email id is ganesan98655@rediffmail.com

2018


solor panels arrange some angle,panel is flat fitted energy was produced or not why?

1907


What happen if 200 KVAR capacitor connected to power continuesly?

2128


hai now i am working as a electrical design engineer in construction field can i get a job in oil and gass field or power plant project as a electrical design engineer?

1926


What is deference between MCB & MCCB & ISOLATOR

2123


what is the difference between the characteristics of two different phase bushing of any transformer

1816


What do you mean by Stimulastion Test in Diesel Genarator / Why & when it's conducted ?

1658


How can I calculate ISF of current transformer?

3643


Can an inverter be used as a converter? How?

1947


Dear sir, By which formula u can calculate for a particular kv line there is a range of mw.

2140