Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

I have 800 Amps MG Fix type breaker It is in on line & it
has been given only UV (under voltage)coil connection for
tripping purpose.now it is not working properly means its
getting tripp so how can i replace it or how can i rectify
the problem without destrubing my load??????????

Answer Posted / karthik

Check with the wiring diagram of the panel and connect the
two wires going to the relay trip coil to a constant
supply.then remove the relay.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How much current will a 5 HP delta connected motor at no load will take?Is tat need a starter

7779


What happens when ac supply is given as excitation voltage instead of dc supply

3809


HOE WE CAN IMPROOVE BY USE OF CAPACITOR

1971


How a band pass filter is constructed?

1072


Please, if 1kw is equal to 1.25kva; how then do I know how many kva in 7.5kw?

1669


What is synchro?

1177


what is the difference between ac motor and dc generator

1866


Differentiate between magnetic field and magnetic flux?

1136


what are the assumptions made in swineburne's test?

2181


what kvrah y we need to take the readind of that

2117


What are the disadvantages of thermal power plant?

1098


how the B-H loop obtain under the static condition

2341


I want to replace the 3 KW DC motor with AC motor so what should be the rating of AC motor? Details Of DC motor to be changed with AC are - Kw - 3, Vf - 310, If - 0.15, Va - 400, Ia - 13, RPM - 2400

1819


This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.

2481


what irequirment need to be followed when working on live equipment

1799