For testing 33kv cable hipot testing. How much kv we have to
Apply .Give in details.
Answer Posted / sunil choudhary
FOR TESTING 6.6KV CABLE HIPOT TESTING.HOW MUCH KV WE HAVE
TO
APPLY .GIVE IN DETAILS.
sunil choudhary
| Is This Answer Correct ? | 20 Yes | 15 No |
Post New Answer View All Answers
tell me about roaster switch .& what is the function in transmission & distribution?
In our plant we have installed new MCC with ELR and CBCT which is detecting some leakage current in the system but it leading to some confusion when to check that in which feeder which is drawing current we put off the whole panel itself but still CBCT detecting some leakage current so can anybody ans me , where i am going wrong or how to detect whether its actual leakage or CBCT malfunctioning.
0.5,1,1.5,2.5,4.0.6.0,10,16 square mm electrical wires how much take maximum current in 50htz
how do i commission a distribution transformer knowing all its ratings and transformation ratios?d
why not starting switch first connect in direct on line starter?????
What is meant by coupling capacitor?
If you don’t have coal, salt and copper, then how would you earth your connection temporarily at a camp site.?
Why in 6 KV XLPE cable termination kit used and why not in 380 V xlpe cable same is not used
What range of speed can you get with the armature control method of speed control of d.c. Shunt motor?
why various test are performed on electrical panels & power cables before commissioning on site & what are these test???
can anyone please help me to find the rupturing or breaking capacity in KA of circuit breaker (MCCB,VCB,ACB etc) of HT and LT side of a distribution transformer...please help with detailed step by step answer...thank you
Sir,In our company there are 3 caterpillar make(capacity:(1) 3.3KV,2.5MW(2)3.3KV,2.5MW & (3)3.3KV,1.9MW) & 1 deutz make (capacity:11KV,3.8MW)gas engines utilised,all are running in paralell. There are three transformer utilised,(1) 6.25MVA,3.3KV/22KV,Impedence voltage:6.7% used for two generator,both are 2.5MW(2)5.5MVA,3.3KV/22KV,Impedence voltage:7.2% used for one generator of 2.5MW & (3) 5.5MVA,11KV/22KV,Impedence voltage:7.8% used for one generator of 2.5MW.all generator breakers capacity of 1250Amps. Sir,I want the details of fault level calculation of generator,transformer individually & for whole system. If you require any information from me.feel free for contact me sir.pl.send the answer of my question as the earliest as possible.
the problem faced on star or delta winding connection??
How to Calculate Current Rating of SDFU (Switch Disconnector Fuse unit) for Protectionof Capacitor Bank connected to Busbar of 800Amp,in LV side of 11/0.433KV, 250KVA Transformer?
before synchronizing an alternator,power factor is leading ,why?