why we avoid parallel operation of diesl generator?
Answer Posted / goodwhisher
to lokesh
this site is very good for good engineers,please dont spoil
it please,it's no a funny matter.
dont answare if you dont know,please.
Is This Answer Correct ? | 9 Yes | 0 No |
Post New Answer View All Answers
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
In both 600/1000 V cable and 450/750 V cable, we can supply 415 V. However for distribution, all utilities are using only 600/100 V instead of 450/750 V. What is the reason?
I have done my m.tech in electrical engg discipline. Can any one please suggest me how should I prepare for getting into phd in iit or nit.How should I prepare for getting into lecturership
how does a liquid starter reduce the starting currents?
Between educational qualification and practical work experience, give us a brief explanation on your practical experience in your past Endeavour that you performed well to the satisfaction of your past or present employer?
can anyone explain 11kV 3core cable megger,hi pot test procedure with connection details?
pls tell me function of closing coil of A.C.B.
What is the different between conventional MCC and intelligent MCC? Common controller or controller for each bucket
What will happen if we on 200kvr capacitor bank(11kv in bus)If there is low load on transformer (1.5 mva 33/11 kv)
Why it is possible to use PWM with a STATCOM and not with a conventional TCR based SVC
what is ground fault in ACB?
How convergengr of nr method is not dependent on selection of slack bus and how gauss siedel method depends?
why actual valve timing diagram is different than ideal valve timing digram of a 4 stroke engine?
How we can calculate the consumption in kwh of motor on basis of kw @100% load, @50% load & @ no load.
How to convert a two phase power into a three phase power in induction machine?