Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Can neutral line also be use as a earthting for
distribution transformer, or we need separate earthing pit
forh the transformer?

Answer Posted / ullas

in the distribution transformer the secondary star side
common point is earthed and taken it as a neutral terminal.
this neutral is earthed 4 place i one mile., in order to
keep the potential as zero volt..
there are so many distribution systems in india.
take the case of kerala, my state.
here we are using the TNCS System.
here phase line and neutral line are given to the consumer
by the supplier. the consumer shall provide an earth pit
for earthing his equipments.
in tamilnadu the TNEB provide additional earth line with
phase and neutral.

Is This Answer Correct ?    7 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to calculate micom relay earth falt time and current sertting

2499


Initially, when the input is not equal to the output — what type of response is this?

1064


Please clarify, 1. Is it required to lay two runs of GI wire along with Armoured LT cable if it is laid between one big mains (63Amps TPN SDF) to small main (32A TPN SDF) with proper glanding termination? 2. If the armoured cable with proper glanding is laid from DB to CNC machine, is it required to run two runs of body earthing to the Machine from DB? 3.If the armoured cable with proper glanding is laid from Substation to Hangar, distance is approx. 100 mtrs, is it required to do earthing at shop area though the primary termination at substation is earthed through gland.

2031


what is the difference between c power and U power acb breaker

6418




2432


why the value of k is more in shell typr transformers?

2002


is there any phase difference occurs while primary and secondary side mutual induction occurs?

2021


whatare the disadvantages occur,if the form factor of transmission will not be equal to 1.11

1866


What will happen if the d.c. Shunt motor opened accidentally running on no-load has its shunt field winding?

1480


1.Can we use 6.6/11KV 300sq mm xlpe 3core cable for LT use (415 Volt). 2. If we use it for LT then what is the current rating

1769


what shoud be strength and weakness to impress interviewer????????

2069


what is a bus post insulator? explain its application in a substation.

12608


how to set relay setting? and example calculation...

2046


How can we calculate the transformer rating if the load calculated is 1000KW (11Kv Supply)?

1084


why are u join ntpc

2170