Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What are the saftey parameters in transformers?

Answer Posted / maharaja

1.IR VALUE SHOULD BE MORE THAN 3MEGA OHMS FOR 1KV
2.PI VALUE SHOULD BE MORE THAN 1.4
3.TAN DELTA VALUE SHOULD BE LESS THAN .07%
4.ALL TRIPING AND INTER TRIPING SHOULD BE CHECKED.
5.AFTER CHARGING WE HAVE TO CHECK THE NOISE.
6.AFTER CHARGING WE HAVE TO CHECK THE WINDING AND OIL
TEMPERATURE 4 EACH ONE HOUR INTERVAL.

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I have a situation to design sub-Distribution board/Panel meant for feeding power sockets. In the incomer CAN i Take TP MCCB with Neutral Link and All the outgoing feeders with to sockets with TP MCCB and Neutral Link? P.S : My System is IT Earthing

1824


What is meant by turbo alternators?

1218


wheather the size of windings in motor and generator are the same

2024


WHY EARTHING NOT NEEDED IN BATTERY IN SUBSTATION

1975


HOW WE CALCULATE CURRENT IF THERE ARE NOT PRESENT ANY AMMETER OR MULTIMMETER??????

1880


how we can set the IDMT relay.

2226


How to test IR testing & magnetic balance test

2009


How to decide no. of Step and Kvar for APFC Panel 40 kvar MD: 33.12 KVA Avg pf : 0.8540

1107


single phase power supply give to separate one steel coup with water, what reaction create

2093


how to size H.T & L.T Panel ?

2138


For electrical designers what are the standard should know? i want learn about this standards. how to get information/reference. anybody help in this regards please.

2151


why i can not use thimble on capacitor duty contactor

1365


specific difference of ICT&Auto Transformer

1902


should %impedance be high or low in a power transformer? if so why?

1933


the site measured knee point voltage of protection class CTs should be greater than rated knee point voltage? what about meetering class CTs. Should it be below the rated knee point voltage?

2293