Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is C.T, why it is used and what care should be taken
for that while connecting?

Answer Posted / manoj patel

It is called as current transformer which is used to
transform higher range of current to lower range. It's
output is used as an input to protection circuit and
mearsuring instruments as the protection circuit and
measuring instruments are designed for lower range of
currents.
Care taken....If ther is metering core then all metering
instrument must be connected in series of S1 & S2
terminal.Same for protection core.
If there is single core CT then whenever its secondery is
not in used it should be shorted.

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the basic components of the feedback control system?

1038


How to identify the start and end of 3phase 12 lead motor if U1, U2, etc numberings are lost or erased.

2135


please send me latest & previous years question papers for IOCL Technical level questions

1864


What is meant by impedance? difference between high & low impedance ?

2050


WE HAVE THE DC RECTIFIER 1500A, INPUT VOLTAGE IS 3 PHASE. HOW TO CALICULATE THE LOAD? 3 PHASE SIDE EITHER dC SIDE. PLEASE SUGGEST ME

1866


Air circuit breaker safety

1401


How many double suspension hardware fittings are required on a double circuit transmission tower?

1908


For refrigerators the motor current is raised beyond its rating on both conditions when the voltage of the system is more(say 270v) than the rated voltage(220v) as well as when the voltage of system is less(say 160v) than normal voltageof 220v, why explain?

1959


After taking shutdown of 11kv feeder, if you see 5kv by phasing stick in the cable side, is it possible to close earth switch in cable.

2346


what is the main difference between power devices and signal devices

2171


What are the ratings of VCB, MCB, MCCB, SF6, ACB, and OCB?

1544


what shall be no load voltage of 132/33 kV transformer ? is it 33 kv of 34.5 kV

2176


HOW WE CALCULATE CURRENT IF THERE ARE NOT PRESENT ANY AMMETER OR MULTIMMETER??????

1845


I NEED RRB APTITUDE QUESTIONS AND MODEL PAPER,PLEASE SEND MY E-MAIL joo28_eee@yahoo.co.in

1893


what will happen if OLR CT in all phases are short circuted

2176