Answer Posted / venkat narayana
Every body knows that ELCB ---> Earth Leakage Circuit
Breaker it itself indicate that whenever Current leaks and
go to Earth then it trip the circuit that called earth Leakage.
But where as RRCB Residual Cuurent .i.e sum of all Vector
sum is not equal to ZERO that is called Residual. Whcih
flows through the neutral, THis can set according to our
Load condition, that is it trip under Unbalnced currents.
Ir+Iy+Ib = In = 0 Noraml Condition
Ir+Iy+Ib NOt equal to ZERO, under unbalnced condition.
Further details can contact : venu24502yahoo.com
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
How to calculate earth fault current for 6.6 KV , 50 HZ , 756 Amps , 3000 RPM , 0.8 PF generator
if a.c supply is given to the motor,, what happen?
ult of expression 'document.FrmQF.myem
Why the symbol of register is "zig zag"
What is knee point voltage?
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?
What are the effects of electrical faults?
Show Details FROM:Muhammed Ikram TO:qa@allinterview.com Message flagged Saturday, June 4, 2011 10:07 PMMessage bodyHello all, i want to ask a question to all of you that what is VMM (voltage monitoring module )? how it work,s? i heard somewhere that it compare 1 phase voltage to other phase voltage. but there is also some setting on it. how to set it,s setting. please tell me briefly. Thank,s and Regard,s. Muhammed Ikram.
EXPLAIN THE TRANSFORMER MAINTENANCE?
What is the high series capacitance winding on high voltage power transformer ?
The height to which the liquid in a tank to be maintained for a certain constant velocity?
I just purchased a 4 position cam switch to be used to operate a 3-speed blower motor. The motor is a 10 amp motor and has 3 wires that are used to control speed. The cam switch was rated at 660V 20 amps but when I received it, I noticed that it has AC-15 operational current rating (Ie) of 4/5 amps. If I am reading the label correctly. the 4/5 amps is related to 440v/220V (Ue). Other ratings are AC-3: 5.5A, AC2: 7.5A and AC-4: 1.5A. My questions are 1) Is it safe to use this switch with the motor I have 2) what is the difference between the 20 amp Ith ratting and the Ie operational ratings?
How much should be the load percentage for 15kva Inverter and Iinut & I output load with Calculations
A double circuit with dog conductor 66KV Transmission line from wind farm evacuation to feeding substation having capacity of 25MW for transmission. Can same transmission network be considered for further expansion of Power & how much in MW. If we need to expand next 10-15 MW more will there any augmentation is required in transmission network? Kindly reply asap.
what should be the ideal gauge of wire (In sq mm) for different loads in Ampere?