explain in detail HV & LV bushing connection in power
transformer (110 / 11 kv 16 MVA)
Answer Posted / sudhirkumar singh
THE HV BUSHING i.e 110KV SHOULD HAVE THE CAPACITY TO WITH
STAND THE RATED KV i.e 110KV,AND IF IT IS HAVING THE WITH
STAND CAPACITY MORE THEN THE RATED KV THEN IT CAN BE
CONNECTED TO HV OF THE POWER T/F.IN SAME WAY THE LV BUSHING
SHOULD HAVE THE CAPACITY TO WITH STAND THE LV RATED VOLTAGE
i.e 11KV,THEN ONLY IT CAN BE CONNECTED TO THE LV OF THE
POWER T/F i.e OF 16MVA.
| Is This Answer Correct ? | 12 Yes | 4 No |
Post New Answer View All Answers
What is electrical diversity factor in electrical installations?
when qty of cable being purchased is not sufficient according to the standard,what should the inspector do to ensure its quality according to the standard?
what is the reactance,capacitance & impedence electrical armoured & unarmored Cables.
we have one oven for 12 zone we are installed ir lamp in oven we control load from thyrister and 0 to 5vdc so our zone no 8 getting bright in fraction of second so what we do.. Please answer
After doubling voltage from solar cells & use step down voltage transformer can we get high current output with low voltage.
what is meant by residual over voltage & residual earth fault ?
explain transformer ct connection?
compare between starting charactristics of synchronous motor with those of 3Q Squirrel cage induction motor
A parallel flow heat exchanger will perform better than a counter flow heat exchanger. State if the statement is true or false.
I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.
What's the difference between non break power supply and non break non short break power supply
How to test the vector group of a Yd11 transformer? what are the relations to be checked between various vectors to confirm this vector group?
sir i used 3 hp of motor for spraying pump, other home light and other home items which size of allminium pvc wire ix used
A ii kv 1200 A Breaker combination fixed in a cubicle. How many ampere Fuse is required? If fuse is not using, Why?
what is the acceptable value of TAN DELTA and dissipation factor for 11kV, 1.75HP Motor?.