Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Do you know how to joint the H.T and L.T Cables?

Answer Posted / jeeva

first we have to know why we need to join HT cable to LT
cable

Is This Answer Correct ?    4 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what will be the min and max voltage flow from neutral to earth?

1595


What is the Basic Difference bitween Long Shunt Connection and Short Shunt Connection in DC Generator?

2393


How u can give the overload setting to any motor protection relay for a HT motors with formula and Example?

2237


what are the values of VRY,VYB,VBR,Vry,Vyb,Vbr,Vrn,Vyn,Vbn for Magenetic balance test of 100 KVA and 63 KVA Distribution transformer

3025


What is resistance of 50meters, 16sq.mm, single core copper cable?

1968


Define piezo-electric effect?

1187


why using transformer and thyristor switch in 3 phase apfc panel

2930


what will happen reduce the transformer voltage from 415v to 406v, is it save the energy,? are this methodis good to reduce the energy.?

1570


if we give 60 hz single phase supply to the transformer used in europe , than what will happen

1988


neutral earth resistance testing is it possible for transformer while in load condition

2015


in non technical way how can u define POWER FACTOR??

1875


Draw the vector diagramme for Asynchronous Induction Generator at noload,half load and fullload.

2041


I am designing new project sub station with 220 kV / 11 kV, 40 MVA capacity. This project have many recifier sets, which can generate 3rd harmonics. Now I have to select vector group of This transformer. To minimise 3rd harmonics, what care should I take in selection of Transformer Vecrtor group? If it is Y-Y with open Delta tertiary then what should be the rating & voltage of Tertiary Winding?

1916


in my industry we are using 3 step up transformers for induction heaters..i.e 415/580v and other are 11/440v.in power consumption does a step trnsformer makes any difference compared to step up?? plz explain

1897


hai iam arunkumar. i have applied for an section enginner in rrb. i want lat 5 years solved question papers. if u have please sedn it to arun30682@gmail.com

1876