Answer Posted / chinna
calibration means it is a process of making the instrument
gives the predefined value.
| Is This Answer Correct ? | 8 Yes | 11 No |
Post New Answer View All Answers
WHAT IS TMXT IN TEMPERATURE FOUNDATION FIELDBUS.
We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.
Draw a great bridge circuit.
how to connect transmitter measuring sulfur process? 1-by using long impulse line or 2- by using coated short impulse line
few questions on RS 232,1 question on relationship of impedance and turns ratio, many questions on flowmeters
how do u calibrate the vacuum transmitter if it shows more reading
what would be the minimum flow rate that we can measure on rotameter..?
Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72
Can u tell me the principle of the tc,rtd,level switch,pressure switch ,transmitter(pr flow level temp.),vibration...plz
how the arrangement of equipments done in control room
i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....
Calibration procedure for Electro magnetic Flow meter
What is the PLC configuration in Cement industry?
Dear Sir/Madam,im going to attend Hpcl written exams on feb 17th in instrumentation stream..can anyone send me the HPCL model papers and pattern of HPCL ....i ve not yet attended anything in HPCL...so i dont know how it comes...so just i need some model test papers and pattern ..pls help me friends...
in which principle pressure tx,level tx ,flow tx,temp tx ,control valve works?