Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why VCB and SF6 breakers to be used in HT used by cant ACB
of higher rating to be used for 11kv and 33kv.

Answer Posted / x man

DURING SWITCHING THEY PRODUCE HIGH ARC,SO BY USING VACUM
AND SF6 THE ARC CAN BE EFFECTIVELY QUENCHED.

iF ACB can be used every were they why do we need at the
other protective devices.so every thing has purpose for the
invention.

Is This Answer Correct ?    23 Yes 14 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to calculate of maximum demand if given 628kw, 785kva, 0.8 p.f.

1640


What is difference between safe PLC and normal PLC

1586


For high frequency application we use which transformer?

1909


what is the maintaining Cf in UPS.

2339


How to Calculate KA Rating of Main LT Panel

1732


list the advantages of RCCB over other circuit breakers?

1696


Why MCCB is Getting tripped sometimes when there is no load in the Midnight ?

1960


calculate external resistance values to add to the rotor of a slip ring induction motor. STATOR- 415 V, 3 phase delta, 1100 A, 50 Hz, 1490 rpm, pf 0,86 ROTOR - 660 V, 590 A, 50 Hz. STATOR current at each steps STEP1-600A,STEP2- 800A,STEP3-1000A,STEP4-1100A.

3547


what's the difference between abs/inc encoders. apart from the position remembrance what are all the other differences. and what's mean by grey code.

2069


please I wont know how to calculate the vector group for power transformer ZNyn11 best regard.

1831


What is Delta Connection? What is meant by Forward Delta & Reverse Delta & How Will be the Connection in Power Transformers?

2257


What is the tests required for a 132 kV, 400 kV , 765 kV for a Circuit Breaker and Power Transformer before commissioning ?

1551


How to calculate the multiplying factor for energy meter with ct ratio given

2008


What types of question are done for diploma students in aptitude test

1629


What will be the impact on motor performance if a LT motor is rewound with changed motor winding data as given below:- Original winding data: total 04 wires = 02 wires of 17 SWG + 02 wires of 16.5 SWG. Changed Winding data: total 03 wires of 15.5 SWG wire size Motor rating: 160KW, 740RPM, 415V, ID FAN application. Normal Running Current = 95% of FL Current.

2017