Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How will you Protect aeroplanes and Ships from Lightining?

Answer Posted / raam

for aero planes lightning is not appplicable since not
connected with earth during travelling. for ships, through
franklin rod systems

Is This Answer Correct ?    8 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Efficient electrical earthing in hard rock area

1505


Do closed loops systems require manual input?

1140


what curve and rateing would you use for a three phase 0.75kw motor?

1929


What is relation between mu(nought) and epsilon(nought)?

1474


What is the difference between Droop vs Isoch Control?

2367


What is polar plot?

1117


Where voltage are high and current to be interrupted is low the breaker preferred is:

2227


When we use air circuit breaker, it has O/L protection ,time delay SC protection, Instataneous SC protection & ground fault protection. They all have some setting range. But what is the suitable/allowable setting for the above protection which will be safe for the equipment? For example-O/L protection setting have a range of (0.4,0.45,0.5,0.55,0.6,0.65,0.7,0.8,0.9,1.0)xIn Time delay SC protection have a range of (1.25,1.5,2,3,4,6,8,10,12)xIn Time delay setting is 0.02,0.1,0.2,0.3,0.4 Instataneous setting is fixed to 20xIn Gound fault setting is given 100A,300A,600A,900A,1200A This setting are for 2500A ACB. So what will be the basic allowable setting for the above protection? is there any formulae to calculate this<

2090


100 MVA 3-phase alternator with earthed neutral has a reactance of 5 ohms per phase. what will be the fault MVA of generator.

2290


there are cam operated switches - why we call cam operated , What is cam ?

1856


What can you contribute to the progress of our Company as an employee if you are selected?

5355


how to get bearing & winding temperature of an induction motor?

1952


Define ohm’s law for a.c (alternating current)?

1002


how open delta PT works & what is its construction?

2190


design of IGBT firing circuit for 11KV

2576