how to determine capacitor bank capacity of one plant..
Answer Posted / thowsif_emerson
Hi If We know the plant:-
Input Initial Power Factor:-
Input Desired Power Factor:-
Input Load KW :-
Then we can cal the Required Kvar i.e capacity
of Capacitor bank...
| Is This Answer Correct ? | 25 Yes | 2 No |
Post New Answer View All Answers
How to find ampere on ht side for selection of cable size ???
Why power factor should not be in leading (capacitive) mode of any load.
In a power conditoining unit (inverter) of a solar plant when we measure the d.c. current fed by different strings of solar plates to inverter, the current in the negative wire is less almost by 1 ampere to the current in its positive wire say current in positive wire 5 A , then current in negative wire of the same string is 4 A. Since the current entering should be equal to current leaving then why the current is noticably less in negative wire.
Which level of the Transformer oil got dielectric strengh? And why?
what is transient enclosure vltage , very fast transients, very fast transient over voltages
we can run 2phase as 3phase .what will be the differnce with respect to phase angle, power, current between the two modes
If we have to feed a housing complex having load 8MVA, than what would be the better option, either we first step down 33kv supply into 11kv & than 430v or we proposed no of 33/.44 kv transformer, also which option is economical?
What is the problem of internal failure in ship engine telegraph system norcontrol?
How to Decide(calculate) Bush bar size for copper and aluminiam ?
What are the different circuits in thermal power plant?
how we can explain arc heatng?
how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?
what are the different methods for the starting of a synchronous motor.
If any HVDC line is going with positive & negative(the negative usually have return path of current with earthing electrode). Now the question is if this HVDC earthed electrode which is using as return path and earthed any nearby 400kv or 220kv AC substation equipments. which will be the impact of this on AC substation & its equipment, how severe may be this and what should be the minimum distance require between HVDC earthed electrode and AC substation equipments? It's really an high engineering level question...Dare to answer and increase your knowledge.
what is the reason for indication of light in the earth lamps of main switchboard.if there is an earth why does one lamp get dim and the other two bright.