Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

if we convert kw into Ampers,which one formula use by
us,pls tell me?

Answer Posted / sameer

First covert kw to kVa kva = Kw / PF(0.8)
Rated full load current in A = (Total connected load in
kva / sq.rt * 3 x Supply Voltage) x 1000

Is This Answer Correct ?    8 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

why current flow to the opposite direction of flow of electrons???????????

2218


at work we have a 3 phase motor but on testing one phase isnt getting a reading. it runs 24 hours a day all week. stops and starts well no noise or heating. the phase isnt down to earth.is it just a bad meter reading or not? phases one and three came up with a resistance reading of 0.4 but phase 2 couldnt get anything shows up as open circuit.

1721


Hi My dear all Friends, There is a question regarding HVAC Engineering and widely used in Power Projects. Question- What is the diffrence Between REF, SEF and Differential Protection....???? Where REF - Restricted Earth Fault SEF - Senstive Earth Fault.

2226


what maximum range of star & delta in hp or kw ?

1751


what is the purpose of shading ring or shading coil in electrical equipments.

4537


are there rmu for 3 transformer?

1945


Name the test signals used in control system

1341


Why electrical power generation and transmission done in 3 phase system not more than 3 phase ?

3132


What is the formuala to calculate the rating of motor protection circuit breaker

2261


What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.

2771


we have 3.5MVA-11/6KV transformer. how can we calculate earth fault current and NGR calculation?

1582


How many types of electrical earthing are there?

1263


Why choke coil is connected in series with starter in tubelight??why starter is connected in parallel to tubelight??

3435


How to design the NGR Resistance

2132


There is air in a room . the top and bottom of the room are at constant temp. T1 and T2. DRAW THE temp profiles if a. T1 greater than T2 b. T1 less than T2

1949