How much pole motor can be desion for 415 volt ,50 hz.Power
supply. in pratical condition .
Prakash veer singh
Answer Posted / prakash veer singh
Dear Ali
I know better that Motor supply voltage rating is not
depend on motor pole nombers .its depend on motor winding
turn.
| Is This Answer Correct ? | 1 Yes | 2 No |
Post New Answer View All Answers
why various test are performed on electrical panels & power cables before commissioning on site & what are these test???
how much UPS neutral erath leakage current.
During Starter Panel Com missing I Found The Main Incomer 40Amp MCB 10KA Trip When Motor Change Star To Delta Motor Rating 20HP BUT When We Use Same MCB To Other Motor It Does Not trip Or What Is Necessaries for Star Delta Starter MCB SFU MPCB OR MCCB And What are The Breaking Capacity of MCCB in the Motor above 15HP
L.A. (Lightening Arrester) is located at a place from where transmission line enters the transmitting substation. So L.A. (Lightening Arrester) is the first equipments which has to encounter with lightening, high voltage surges and switching surges. It has to absorb energy of lightening, high voltage surges, and switching surges. L.A. (Lightening Arrester) is made up of layers of semiconductors. If these layers can not tolerate energy released by lightening, high voltage surges, and switching surges the L.A. (Lightening Arrester) blasts.
what is the function of bearing in dc mchine" and where it is placed
The inventer is a battery, but if lost current at home u will turn on the fan but the is AC and inventer battery is dc . Then how the fan was rotating. What device Or machine in fan converst the Dc power to Ac power
In india, according to trade theory above 5 HP motor reqired star delta starter. But we R connect 11 KV motor with 14MW in Direct to line ( With VCB starter combination) Can U Guess, How it is possible ?????
100 MVA 3-phase alternator with earthed neutral has a reactance of 5 ohms per phase. what will be the fault MVA of generator.
In single phase capacitor motor, if the motor rotate reverse direction then how much power will be consumed by the motor and why?
work of choke in florocent tube circuit ?
why asa method ZPF method is more accurate than ASA method?
sourse is 66 KV / 350 MVA, transfarmer is 1000 KVA 6.6 / 0.415 kv, iF fault is 28.75 MVA on 0.415 KV Bus then calculat the Transfarmer Impidance
Why temperature rise is conducted in bus bars and isolators?
what parameters are should nessary for control technic dc drive(in rolling mills)?
I want to design a heating coil of 80/20 nicrome for 3.5KW please give me the calculations choosing for physical dimensions assume coil voltage will be 110V AC assume necessary conditions