Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is Specific Gravity of the Electrolyte used in Lead
Acid Battery????What is Unit????

Answer Posted / ravi

It Should be 1.25 to 1.30,

No-Unit for this....

Is This Answer Correct ?    14 Yes 9 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to Design green buildings services? What is the advantage to design green building?

1747


working principle a.v.r. ?

2342


What is touch potential and step potential?

2075


In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes

744


how does an encoder work???

2463


Explain thin film resistors and wire-wound resistors

975


how to electrically make connection to ferroli GN2N?

1883


why we have and use 3 phase not 2 or 4 or other in power system?

2070


What is the formula of frequency ?

1410


State kirchoff voltage law?

1082


v/f drive basic princeple

2420


what is Anti-pumping?

1888


HELLO EVERYONE, I RECENTLY HAVE FOUND ONE PROBLEM, I WAS TAKING NO LOAD TRIAL OF AN HT MOTOR 920 MOTOR , 1440 RPM , 6.6 KV, WITH AUTO TRANSFORMER. AT 450 V, LOAD WAS 40 AMP AND SPEED WAS 250 RPM. BUT AS WE INCREASE VOLTAGE FROM 450 TO 480V, LOAD BECOME 41 AND SPEED REDUCED TO SOME RPM . SO WHICH PHENOMENON ACTED HERE FOR REDUCING SPEED.?? AND IS IT HAPPENING ALWAYS OR IT IS RARE? I ALSO HAVE FACED SUCH PROBLEM WITH FEW LT MOTOR ALSO.

1908


Why do we mostly prefer to generate and distribute electricity in 3 phase and not in 4 phase or 5 phase?

1165


In convertor can we use rectifier thyristor in place of invertor thyristor with explain.

1756