Answer Posted / surya
I think loop checking is another way of calling "feedback"
...
m not sure abt it..
| Is This Answer Correct ? | 19 Yes | 81 No |
Post New Answer View All Answers
what happen if i increase height of displacer type LT.accuracy or sensitivity are affected.why?
please tell me what is a light up procedure of Cfbc boiler and what it's axuillaries of cfbc boiler?
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
How to work togather like sov,limit switch,proxy switch and booster in xv
what is use of communication wire in multipare cable(oil and gas field), why this communication wire not used in single pair cable?
Why upper weighing limit of electronics balance is 90% of the total weighing capacity?
Explain an adaptive / self-tuning controller’s major draw card.
Explain PID controller tuning & any one method used for it.
it is possible to check the fail safe condition in pressure transmitter. if possible how?
the 3 most common transmitter protocol being in refinery or qatar gas and aramco.
OBJECTIVE TYPE QUESTIONS OF ANALYTICAL INSTRUMENTATION
what is commisioning procedure,2)what is is the main work in commisioning in the field tx to dcs, plz send me detail
give eg of how I/P is used in control loops
In dcs panel we are using diff type of modules ?what is module ? what is the use of modules ?diff type of module?
What do you know about gail?