how to install Differential pressure transmitter in gas
line.i need transmitter down side.
Answer Posted / snehal
place the taps side of the line
place the transmitter beside/above the line so that
condensed fluid will drain off
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
pls give me presant awerness quistion and answer in my emailid.
how u choose thermowell lenght n pnumatic C/v size?
we have level transmitter for h2s04 storage tank capacity 10k ,always there are failure of transmitter due to failure of magnetic floats ,please come up with solutions at the earliest.
what would be the minimum flow rate that we can measure on rotameter..?
Can combine control system for Emergency control system (ESD)and Fire & Gas System ( F & G) is possble to built and offer to client? Can such system is as per Norms in India?
how to connect transmitter measuring sulfur process? 1-by using long impulse line or 2- by using coated short impulse line
what is the current pay package for an instrumentation engineer having 2 years of experience in cryogenic technology???????
i want to know the interview format fot gail, instrumentation. pls answer me in habib.sami1003@gmail.com
can we replace a slot sensor (inductive type) with limit switch (potenial free contact / no-nc type).
1.what is the effect of vapour presuure in orifice plate flow measurement 2.which is more effective 2 pressure sensors or one single differential pressure sensor in orifice plate measurement 3.how to design a v/i converter and i/v converter 4.how many type of thermocouple are there 5.how many leads are there in thermocouple measurement 6.how pressure sensors are connected in level measurement in differential pressure method 7.what is the output of capacitive pressure sensor (ac or dc),how its o/p is signal charactarized 8.what is the physical meaning of discharge coeeficient,why it is calculated,orifice plate what is its value,why it is less than 1,Q at upstream is equal to or not equal to Q at downstream of orifice plate why?what is vena contracta in orifice plate 9.why rotameter is called variable area flowmeter,it can measure flow even if area is not varying,why it is made tapered 10.design a 10 bit counter ,which counter you will prefer 11.how to remove self heating error in RTD 12.which is more sensitive pt100 or pt50 13.why thermocouple are connected in parallel 14.what is lead contact error in RTD,how to avoid 15.what is P,PI,PID,PD controller,why there is no ID controller 16.what is override,split range,sequential,ratio,feedforward,cascade controller 17.why we moved from SR to JK and then JK to master slave JK flipflop,give correct reason 18.how to measure level of a closed container which contains vapour and liquid,remember no vapour gas should be leaked,so ultrasonic and capacitive is not an option,design another method 19.how to design horse race counter including sensors and signal conditioning element 20.what is bevelling
Hi Friends i am going to write BARC written test by this month 20th (20-5-2008). So please if any body knows the details about this or having previous question papers pls mail me to kkumarei@gmail.com. For Suggestions give one message to 9962122264
CONTROL VALVE OPERATING IN MANUAL BUT NOT IN MANUAL. WHAT SHOULD BE THE PROBLEM ?
Which language of programing is popular? how can i learn it ?
What are the different types of thermistors used in industries? How to the operation of typical thermistor?
What is the cascade control