Kindly furnish the relation between 7 days strength & 28
days compressive strength of Cement Concrete cubes. Can you
clarify whether the relation gets altered due to WATER-
CEMENT ratio?
Answer Posted / manohar cherala
The relation between the strength of concrete at lower age
and 28 day depends on may factors like chemical
composition,fineness of cement and temparature of curing.
Mixes with lower water cement ratio's gains early
strength's more rapidly than that of concrete with higher
water cement ratio's.Because of arrangement of cement
particles more closer in lower water cement ratio's and
formation of continous gel which gives more strength.
In general the 7 day strength is not less than 65% of 28
day strength
Is This Answer Correct ? | 23 Yes | 1 No |
Post New Answer View All Answers
calculate the quantity of cement ,sand,bars and aggregate used for 28*4 ft with 4 inch (125mm) thick
Calculate the maximum allowable speed on a horizontal curve of radius 350m if the maximum allowable values of the lateral coefficient of friction are 0.14 and the rate of superelevation is 0.08.
Design a rectangular channel.
Why do we not deduct steel volume to find actual volume of concrete in practical as we have studied that,,, actual volume of concrete = volume of column- volume of steel pls explain with reference of IS code?????
How reactor of SBR installed , is it be over ground, fully under ground or semi sunk ?
what is anchorage length,lap length and (dont remember the last one)
WHAT IS YOUR CURRENT SALARY
How much 1 cum of M15, M20 & M25 concrete weigh?
What will be the exam pattern and syllabus for j.e post of haryana staff selection commision? Advt no. (02/2015) Some people says it would only be objective type question papers while others say it would be same as ssc (1 objective,1 conventional) ?? Please answer this question it is needfull to all.
how can calculate cutting length of diamond ring
what quantities of work done in terms of sq.mts/day/ of 8hrs for each varpenter (shuttering) and Steel fitter in terms of Tonnes. For slabs, Columns etc.?
for 16mm thick cement plastring 1:6 on 100 Sq.m.New brick work,the quantity of cement required is.
In Abutment walls (A1 side) why we are adopting fixed bearing (POT-PTFE)?
if a pipe those configuration (ASTM c 76 class b 450mm dia 2500mm length) fixing for water course those lining of water is 7000 running meter. my question is that if 8 joints of pipe ls leakage and we have not permission to stop the water so which treatment we apply on joint in that in condition.
what is the max. area can we apply the plate load test ?