If an induction motor is restarted before its rotor stop
rotating, then what will be the amount of current drawn?
Is this current will be the same as motor starting current?
Answer Posted / savan patel
IT WILL DRAW MORE CURRENT THAN MAXIMUM SPEED AND LESS
CURRENT THAN STARTING.
| Is This Answer Correct ? | 8 Yes | 2 No |
Post New Answer View All Answers
In the magnetic fluxes, what is the role of armature reaction?
what is the requirement regarding earthing of Single conductor with AWA
What is the actual calculation for transformer short circuit test?.
what's the difference between abs/inc encoders. apart from the position remembrance what are all the other differences. and what's mean by grey code.
Generator,motor and alternator Working principal Please explain easily
what is the function of anti pumping relays? what is KVAR? How it is generated in alternator? What is 3rd Harmonics? What is IDMT relay?
tan delta equation test on alternators
write encoder 17 pins details? pin a;b+, pin b;w+,..pin s & t. what is the meaning of b+, w+? explain;
Why GRR starts from 60% of motor speed why not less than 60%?
How To Convert Apparent Into Real Power Without Knowing Reactive Power?
What are the major reasons for balancing hydro-thermal mix?
hi, in the event earth grounding is not available in a project, is there any other way to make the elcb work? fyi, i have an instant water heater (6.5kw) installed, however if there is grounding in the heating element inside the heater assembly, i will get grounded. thank you in advance to those who will answer my question.
This is urgent!! What is a Thyristor-based 3-ways selector switch with Zero crossing control? how does it operate and where is it mostly found in a system?
We are preparing another project which involves Waste heat recovery from a 1 MW GE Engine. The Engine in particular gives out flue gas at 487Deg C with a flow rate of 5650 kg/hour and this can be cooled to 180 Deg C. This gives a thermal output of ~ 594 KW that is available for input to VAM via heat exchanger / boiler. Additionally 581 KW will be available from engine jacket water (temperature profile 80/ 80 Deg C and a flow rate of 50m3/hr) Our estimation is that 300 TR of cooling is possible with a suitable VAM machine(s). Please advise what is the most suitable arrangement with maximum TR and min Capital expenditure. plz reply me as early as possible
What will be the voltage impact on secondary side of two transformers with different vector groups when both voltages are compared.