Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

will we have to design the UPS differently for both i.e. if
we want to connect the two batteries in parallel and/or we
want to connect the two batteries in series ?

Answer Posted / dinesh desh

which has the Ampere hour capacity greater
& which has the input voltage greater

& what would be the difference in designing the both UPS ?

thanks

Is This Answer Correct ?    0 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

1 Ton is equal to how many watts?

1084


why does a dc machine has high efficiency while working as a generator than as a motor ..

1980


what is meant by rotating magnetic filed

2035


Classify milling machines.

1111


I FINISHED MY B.TECH IN EEE . I AM IN NEED OF A GOOD TRAINING INSTITUTE TO DO COURSES .. CAN ANYONE SUGGEST GOOD CENTRES IN TAMILNADU ,BANGALORE ,OTHER AREAS???????

1985


Why computer humming sound occurred in ht transmission line?

1101


how to calculate earth fault relay current and CBCT ratio

8311


How to calculate the phase to phase clearness of HT /// LT bus bar?????

2058


What should be setting for alarm,tripping and cooling fan on for power transformer's oil temp. and winding temp. indicator?

1927


i want some interview related questions with their answers which can help for attend the interviews...

1628


Why CBCT rating is 50/1A

2832


UG cable sizes were specified in sqmm. But practically its not coming to mesure. What's the reason for that? And how they specify the size of the cable?

1916


What will happened if the neutral of secondary of Xformer ( Star point) Note it's above KVA rated Xformer

1871


What is the Diff. btw Manule Pull Station & Manule Abort Station Switches used in FM200 System??

1837


1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?

2259