how to use single phase supply for a three phase equipement.
Answer Posted / mas
by using phase splitter ( having capacitorin series with
firing angle delayed as 12 ,240 ) we use 1 phse as three
phase
Is This Answer Correct ? | 7 Yes | 1 No |
Post New Answer View All Answers
1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?
In Dyn11 power transformer if any one of the 3 phases connected to earth in star connected side then please explain effect of the current flow in delta connected side of transformer.(In this case if one phase is shorted to ground in star connected side then we observe the current flow in two phases only not three phases in delta connected primary side. Please explain why it is so?)
what type questions asked in hp cl
Is it posible to instal one more SMDB from the existing SMDB and is it practical.
1. what is usage for power factor in industries?? 2.why we need to monitor power factor??
if 6 earth pit value is 1.5 ohm then what should be the number of earth pit to make the value .8 ohm
A 500 V shunt motor runs at its normal speed of 250rpm when the armature current is 200A. The resistance of the armature is 0.12 Ω. Calculate the speed when a resistance is inserted in the field reducing the shunt field to 80% of normal value and the armature current is 100A.
how to work droop ct in generating station
What is step signal?
In aerodynamic turbines which element is NOT there a.stator b.compressor c. Fuel intake system d.fans
please send me previose rrb junior engineer qustion papers
What is the effect of pd controller on system performance?
What is mean by hot and cold loop testing? What is the difference between them?
What is 100% protection of generator? Why 100% is not used but 95% is generally used?
What is the difference between electrical earthing and electrical grounding?