Answer Posted / ashish jain
in case of C.T. It is the value of voltage above which
there is a sudden increase of current i.e. with 10%
increase in voltage, there is 30% increase in current
(approx). below this voltage the V/I
charachteristics is almost linear.
| Is This Answer Correct ? | 5 Yes | 5 No |
Post New Answer View All Answers
As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?
why do we have spikes enough to burn electronic boards, when generators are not grounded
what is mean by Digital Logic Meter (DLM)
How to Prepare preventive maintenance shedule of machine tool.
If i am running of spindle at 2000rpm ,but How to spindle stop at the second I am resetting the machine in CNC machines
any body,pls tell me how to done relay coordination ? how to coordinate by TCC curve?how to read the tcc curve?
On a 3 winding transformer YNynd11, how do you apply REF protection to the Delta tertiary winding that is supplying auxiliaries to a substation?
if flux and load static in dc motor and supply voltage increases 20% then what happened in speed
what is the effect of connecting three phase supply lines to three phase auto transformer output terminals through a fuse of 10Amp and a circuit breaker (MCB). Is this connection permanently destroy the transformer?
generally in LT and MV motors we are using 3.5Coresx16,25,35,50 etc cable for supply.although motors is earthed at two point and having all protection.then why we are using that 1/2 core for earthing the motors.while in HT cable we are using only 3core cable for motor supply.generally lt and mv motors are delta connected and ht motors having star connection.whethere it is having any relation with winding connection( star or delta).all motors i am talking about are dol only.can anybody solve my confusion.thanks...
Two liquids hot and cold in two vessels are there and an metal bar acts as a conductor of heat between the two vessels. what happens then. what happens after 24 hrs?
from where the self excitrd induction generator get the power?why is the voltage regulation is poor of seig?
We have 90mX100m hangar with 16 no.of supporting pillar. It is required to provide power supply on all pillars. what is suggested earthing scheme for hangars.
what is Anti-pumping?