Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is mean of 3 by 2 automation ?

Answer Posted / senthil

for example,consider the three transmitters are in
service.in logic,the three xtr compare each other value i.e
A&B,B&C,C&A. check the diff of deviation b/w the
comparison.the xtrs showing minimum deviation is taken,from
this the mean is taken b/w two xtrs.this is 2 0f 3.

Is This Answer Correct ?    4 Yes 3 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How is PH sensor works ?

1916


what is the current pay package for an instrumentation engineer having 2 years of experience in cryogenic technology???????

4909


how to do dynolab wind speed sensor loop test, how to simulate value,i have simulate mA 4-20mA but not responding in DCS faceplate, please kindly advice me any one.

991


which processor is used in dcs.

2203


Explain Gas Turbine startup and shutdown sequences

4258


what is the calibration procedure for transweigh make weigh feeder?

3944


what is the importance of CV in the control valves? how it is calculated?

2384


HI friends.I am Surya a BTech in Electronics and Instrumentation Engineering.I am going to appear Relince Industries Ltd all India writen test very soon. so plz help me by sendind the probable questions about my subject.My mail ID is surya.barik@gmail.com.

2224


how to calibrate mass flow meter (Coriolis)? Example calibration range: 0 to 2500 kg/hr line size 3" fluid: Etheline glycol (MEG)

2631


We are using Rosemount 5400 series Radar Level Transmitters in all types of Sump Applications having oily water hdrocarbon petrochemical nature. What we are facing the problem frequently is that always getting reading frezzed at some value. If we do power recycling , sometimes it is working . then making same freezing problem. If anybody faced before such type of problem and also having solution , Please give the answer.

2286


hiii.... can any one provide me previous years question paper of hindustan petroleum for instrumentation engineering???

1932


How u measure the massflow in orifice flow measurement techniques

1350


centrifugal compressor interlock? Tell me the parameter at which compressor will trip

3105


I have completed B.E. Instrumentation & control in 2009. i have 3 year industrial job experience in chemical plant.now, I want to join M.E. in external. so, Plese say easiet way and good institute name.

1859


What are the materials available to prepare individually for competetive exams in Instrumentation field? Plz reply...

2018