Need help. 3 phase system. Neutral line arced and melted
upon connection of connector with 3 phase power. Why would
that happen?
Answer Posted / pinky
I have a connector that connects to a piece of equipment.
The connector has many pins mostly for monitoring signals
coming from the equipment and for supplying 3 phase to the
eqpt. When I connected the connector to the equipment it
blew up. The neutral line melted into the piece of
equipment. Why did the neutral line blow.
Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
Is a 300w induction motor used in a food processor as powerful as a 1000w DC motor.
What is corkscrew rule?
1.how many types of relays? 2.difference between ATS& STS?
For high frequency application we use which transformer?
Explain the process of commutation in a dc machine.
Why we use 4-20 mA Analog signal for the PLC input? Why not 0-20 mA? Why not 5-25 mA?
what is the IS foe lightning arrester?
How do we find the rating of a transformer, if it got burnt badly.
What are the special cables required for explosion proof wiring?
Formulae for calculating the transmission line losses for different voltage levels
why swityard is necessrry requirement in any bis power distributin systems?
What will happen if i replace a inductive proximity switch with photo sensor in a machine?
How to calculate fault level of 11 KV system
1. What is differential relay? How it operates? 2.How to calculate the Short Circuit Impedance in Transformer? 3.What is the alternate solution for testing of polarity by using polarity tester while its milli ammeter does not works? 4. While testing the 33KV Busbar by using Hipot kit, what should be the test voltage we have to apply? 5. What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer? 6. Explain how you can give the overload setting to any Motor Protection Relay for a HT motors with formula and example? 7. Why restricted earth fault protection is needed? Why can’t differential Protection is sufficient? 8. What should be the minimum and maximum ohmic value for earthing? 9. Why DC Currents are not used in transformer? 10. What is the Frequency while we step up the voltage from 220V to 11KV? Is it possible? Explain it?
How to synchoronize the generator (with gcb,GT) to grid????? ????? from Grid iam getting power (rated 400kv/20kv) through GT and its goes to UAT.,,ST.,, now my generator(rated 20kv ) ready.,, now iam closing my GCB.,, in GT iam suddenly giving 20kv on that Gt.,, what will happend