deference between DCS and PLC including date processing and
architacture.
Answer Posted / kk
1.PLC -Programming Logic controller .to PLC have faster
scaniing time.like diffrent CPU have diffrent scanning time.
2.like CPU 414-have .1ms scanning time simense.CPU 412 .2ms.
for monitoring and controling SCADA but in scada we can't
change engineering value.only monitoring and controle can
use SCADA.
3.PLC is relay logic control system.when any one RACK CPU
card fauiler then hole system will be stop suddenly.
DCS-Distributed controlle system.
1.DCS hase more space to store data.
2.DCS scanning time faster as compare to PLC.
3.DCS control the system functionlly and geographicaly.
4.area jone can be devided according process distribution.
5.have authority level to change the engineering value in
engineering section.
6.During the fauilure time u can get the particulre
instrument Data.
| Is This Answer Correct ? | 8 Yes | 2 No |
Post New Answer View All Answers
What is 3 selection available when configure the burnout protection for controller
What are the charcterstics of a P&ID controller block for Governor speed raise or lower for a load sharing functionality between 4 Gas turbines in droop mode.
What is modbus?
Linear amplifier.
the output of the common trasmitter protocol in qatar gas are the following
We are using Rosemount 5400 series Radar Level Transmitters in all types of Sump Applications having oily water hdrocarbon petrochemical nature. What we are facing the problem frequently is that always getting reading frezzed at some value. If we do power recycling , sometimes it is working . then making same freezing problem. If anybody faced before such type of problem and also having solution , Please give the answer.
What is motion balance principle?
How will you calibrate PID controller? explain with example.
this site is owned by an nonsense
how to convert cubic metre per hour to newton cubic metre per hour
What is the use of double seated valve?
What is sensitivity in vibration probes..?
explain key exchanges in all security modes WPA,WPA2,TLS?
Calculate the maximum pressure drop that can be allowed to occur across a control valve, so that we can prevent cavitation / flashing from occurring. Use the following formula: Δ P allow = Km (P1 – PvapourA) where, Δ P allow - the maximum allowable differential pressure for sizing purposes, or terminal pressure drop; Km- the valve recovery coefficient from the manufacturer’s catalogue; P1 - absolute inlet fluid pressure; PvapourA - absolute fluid vapour pressure at the inlet temperature; Use Atmospheric pressure = 101.3 kPa, P1 = 1200 kPa(g), PvapourA = 4 kPa, KM = 0.72
why we use impulse line of flow transmitter at 45 deg. angle both side of orifice plate.