As all us know that the capacitor panel is connected to
improve the power factor when it is PF is low. whether we
can connect the capacitor panel on D.G. side(? If it is yes
means why?
Answer Posted / jeyachandran.b
IF PF IS LOW WE CAN CONNECT BUT IF THE PF IS GOING TO LEAD
IT WIIL AFFECT THE ROTOR
| Is This Answer Correct ? | 4 Yes | 4 No |
Post New Answer View All Answers
L.A. (Lightening Arrester) is located at a place from where transmission line enters the transmitting substation. So L.A. (Lightening Arrester) is the first equipments which has to encounter with lightening, high voltage surges and switching surges. It has to absorb energy of lightening, high voltage surges, and switching surges. L.A. (Lightening Arrester) is made up of layers of semiconductors. If these layers can not tolerate energy released by lightening, high voltage surges, and switching surges the L.A. (Lightening Arrester) blasts.
what happen ehen synchronisation is done at below rated speed
In a tap changing transformer where is the tap connected, is it connected in the primary side or secondary side?
please send me previous year questions of jspl through which i could prepare myself for the test.
How relay coordination has to be done? what are the inputs are required for this? Please explain this with calculation method?
in 1-phase 230v,how in 3-phase 440v. in each phase in between 230v.
we have provided 30 nos. relay contacts in panel.I want to know how do we do the numbering for the relay contacts as per any applicable standards
how did i get the competency certificate as electricle supervisor. iam completed my b.tech.but i dnt have any experince, this certificate is required for applyng ongc mangement trainees. what should i do sir please suggested me
from which subjects most of the technical que will b asked for hpcl(electrical).pls help me
Power factor =1.000 at factory in supply. However, PF = 0.8 at motor end. Current = 100 Amp, Voltage = 400 V. What is the power distribution loss? Can I reduce it by adding capacitor at the load feeder?
he compression ratio for a petrol engine generally lies between
How much pf maintan in dg set in 6o% load,when Dg runnig Neutaal Earthing removed what happen.
I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.
Is neutral transformer can be called as control transformer?
Who many reason of ignition fail ?