Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how manys ways dp transmitter can be calibrated having
range of -150 to 400mmwc,what side pressure u will apply?

Answer Posted / naresh makhwani

We always have to apply pressure on the high side of the
transmitter. You cannot apply pressure on the lower side,
though if you will apply it gives you the negative reading.

Is This Answer Correct ?    15 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to tune siemens sipart electro pneumatic positioner..plz tel me..

2089


Question on maha cement

699


how u calibrate pneumatic n motorized c/v?

1918


full process of gas turbin?

2044


for oil & gas industries which zone is normally preferred? why? give its example?

1938


Which type of diagphram use in costic line,DM water line,natural gas line,oil line?

3867


A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.

2114


Describe the functions of the Operator Interface including the considerations related to alarming and display layout/configuration/layers.

2021


Which type of pressure can be measured by these elements?

1090


can any one tell me when ongc placement test and its forms is available????/ pls tell me if u know

2067


hi,i am doing 3 year in electronic and instrumentation engineering. what type of aptitude questions will be asked in a core industries and how can i improve my skills in instrumentation?

2060


To become an Instrument DESIGN engineer, is there any softwares or training to become Instrument Design engineer, plz suggest me, Iam very much interested in designing.

3404


when a magnet is heated?

1920


Derive capacitance to 4-20ma conversion formula / relation in capacitance type pressure sensor?

2185


what will the sending unit in the fuel gauge utilizes?

1844