Answer Posted / natarajanramkumar
Frequency - It is defined as the number of cycles per
second.In india 50 c/s is common.
Frequency = NP/120
Where N is the speed in r.p.m.and P is no.poles of a
machine.
| Is This Answer Correct ? | 59 Yes | 11 No |
Post New Answer View All Answers
how to CHECK CT AND PT AT THE FAULT OCCUR IN GENERATOR RELAY PANEL .
How is the connection of the tap changer on the HV side been made?
what is the minimum (Common factor) insulatin resistance of the following a, 4mm sq wire b, cable from 50 mm sq to 800mm sq
we have one oven for 12 zone we are installed ir lamp in oven we control load from thyrister and 0 to 5vdc so our zone no 8 getting bright in fraction of second so what we do.. Please answer
75 kw motor take 45 amp in no load delta in star 10 amp but in load it will take 160 amp but IR velue of winding above 500 at 1kw ph to earth and ph to ph. what problem it should be?
I don't understand why when we connect high voltage source in DC to electronic motor , we must add capacitor and resistor in parallel ? (I know that we use capacitor because we want to absorb the current that in the first second electronic motor in opposed with current course produce. ) what are the feature of Resistor and in such situation ?
2. A current i=(10+10 sin t)amperes is passed through MI type ammeter. its reading will be.........
ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?
whats the application of voltage regulation? and whats the voltage regulation's device?
I am an American living in Vietnam and I have recently gotten a refrigerator from Japan and it is rated for 100 vac, but the power here is 220 so I bought a voltage stabilizer it has a 1 kva output rating. Can you please tell me what the amperage is? I'm confused and without a working fridge.
what happen ehen synchronisation is done at below rated speed
3 shows a 415 V, 3-phase generator supplying a 3-phase 415/110 V transformer. Draw the individual and combined impedance diagrams to a base of 10 kVA. Determine the system fault kVA and the fault currents at the 415 V and 110 V busbars for short circuit faults on the transformer input or output terminals. Work in p.u. values of impedances.
What is FM200 Gas??Applications........
How do we calculate the Out put voltage of generator, after the excitation is being given?
I have 1500/1A CT If i connect this CT in 6.6KV bus bar means what will be the voltage present in CT?