Answer Posted / md. zakir hosen
I just want to say shortly,
KW or MW or W is used for meaning of Electrical Power.
and HP is used to meaning of Mechanical Power sometime it
also known as BHP (Break Horse Power)which is found on the
shaft.
more info and online Earning:
http://a2zengineering.blogspot.com/
| Is This Answer Correct ? | 10 Yes | 3 No |
Post New Answer View All Answers
i have been tasked with a design of protection, metering and control(PMC) relay panel extension to accommodate all PMC relays.There is an already existing panel where this one will be built.What are the design aspects for this kind of project? thank you.
how to read idmt curva
1)what is the function of a frequency inverter? 2)If a few frequency inverter are connected onto a device network,what are the two setting that will ensure the frequency inverter work properly on the network. 3)whats is the name of the input sensor for weigher? 4)How to confirm that the load cellis faulty? 5)Describe briefly the steps to validate that the weigher is working properly? 6)Describe the procedure to validate the flowmeter accuracy? 7)Describe briefly the steps to validate that the tempreture sensor/transformer is working properly. 8)what is the adjustment that need to be done when you are calibrating the temperature transmitter ? 9)what are the safety measures to be taken before disconnecting motor for rewinding. 10)whats is the synchronous speed in rpm of typical 4pole 50hz motor? 11)whats is the formula for kw, ohm's law 12)if a 3phase motor is rated 3kw,415vac,what is it's rated ampere?
what is die electric strnth of transformer ?
what is circuit breaker in transfomer and where it used
How to Design green buildings services? What is the advantage to design green building?
Dear Respected sir how to test ABB REX521 protection relay by relay tester.
ASTM D 3455 - Standard Test Methods for Compatibility of Construction Material with Electrical Insulating Oil of Petroleum Origin has been used for Testing Transformer Oils with a product placed in it. Aged Control Oil has a Power Factor of 0.032% at 100°C. Aged Oil with a Test component has a Power Factor of 0.093% at 100°. Is this increase acceptable? If not why? How much increase is acceptable?
what is different between relay and plc?
How to calculate cable size in HT AND LT
Which Class insulation is prefered for the sandwich Busducts ? Why?
what is auto re-closer?
one conductor length is L.and i am strech uniformly this conductor and made length is 2L.so resistance of this strech conductor is R=4R..but i want to know about area of stech conductor hows it become a/2..
How to select the gauge of wire for winding of motors? How to select number of turns for winding of three phase induction motor?
l&t switch FN 63 handle position can we change