Answer Posted / shalini.b
NO means normally open - during off condition or any other
abnormal fault condition the contact will open therby
forming a open circuit providing no path for the flow of
current.
NC means Normally close- during normal operations the
contact will be closed forming the closed circuit
| Is This Answer Correct ? | 67 Yes | 15 No |
Post New Answer View All Answers
How to calculate VA rating for CT or PT or Control Transformer?
how to test reverse power trip?
although ckt breakers have taken the place of old fuse. But instead of it , these older ones are still used in the industries and homes ? why .... what are their advantages and disadvantages ? which one is leading and winning the race and competition ?
Why does the adjacent zone of protection overlap?
earth also having a gravitational force (magnetic field of north and south)but it attracts any object compare to this theartifical magnetic cant perform same as earth why?
What was the Dg set radiator and lube oil temperatures trip in ACB
What is dynamo function in DG sets and draw block diagram?
What does the term power factor shows?
What is Control & Relay Panel? And Remote Control Center?
What is the meaning of C1, C61, C91 cable
Given a collection of points P in the plane, a 1-set is a point in P that can be separated from the rest by a line; i.e. the point lies on one side of the line while the others lie on the other side. The number of 1-sets of P is denoted by n1(P). The maximum value of n1(P) over all configurations P of 19 points in the plane is 18
Cables Construction hi friends, 0.6/1/1.2 kV LV , DC and Control cables are concentric copper conductor what does its means and what is the use of concentric copper conductor,and are this with copper tape shield or copper screening, ? thanks
What is mean 2XWY
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes
During Testing of Maintenance Free Earthing, How deep should be the Spikes of Earth Test Meter should be inserted in the soil(one spike is 15 Meter & Other spike is 30 Mtrs away from the Main Earth Electrode. Because, recently, we observed that when spike is inserted 3-4 Inch in the earth- results are better, If spike is inserted 1 feet deep than results are increasing.