Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

wts d diff b/w C.T. & P.T.?

Answer Posted / sripellirajukumar

hi ,
this is rajkumar

u were said about r very silly points
here somewhat depth differences there as follows

current transformers

1.primary winding turns r very less .
2.CT means it is step up transformer.
3. the primari and secondary winding turns ratio is in the
form of 100:5.
4.this CT is used to measure currents in high voltage
alternating current ckts.
5.secondary winding of CT must be closed.it should never be
left open under any circumstances..other wise it CT
winding insulation will damage,and also that will effects
on the people who r doing the measurements.

potential transformers

1.primary winding turns r more as compared to secondary turns
2.PT means it is step up transformer.
3.the primary and secondary winding turns ratio is depends
on the range of lowrange voltmeter (which is used to
measure voltages in lab)
4.PTs r used to measure high alternating voltages.
5.here no need to specify about closing of PT because we
will be connecting low range voltmeter...


thanks,,,,,,,,

Is This Answer Correct ?    11 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What are the basic components of the feedback control system?

1056


How can we select suitable capacity generator for three phase load (inductive load) and how to take study analysis in 3 three phase load system ?

2158


how we can come to know that motor winding resistance which showing by DMM is right or wrong???is there any chart or something that we will compare & check???

1914


What is conventional thermal current (Ith)

4449


If 24 KVA AVR having Input voltage 200-400v, Output voltage 415+-1%, what will be the voltage if Load is 13A.

2099


What is meant by derating factor?

1231


What is the criteria that generally follow by distribution licenses to fix contact demand of their industrial customers?

1524


what is effect of 5amp fuse on 2mva pry protection of transformer

1856


we have 2.2kw,Y,3000rpm motor but 6leads found in TB what happen if we connect in delta?

1929


Hi,iam a diploma in electrical engineering.rtd from indian air force in apr 2007.prsently working in reliance next link as a network maintenance engineer since 2007,can i get a job in motherson sumi.

2376


what will be d.g. capacity to cater together for 14hp A.C. load & 3kw lighting load

2006


Z transform is use when system is not a) converges b) diverges

1683


can anybody send the rrb chennai &rrb bopal question papers of 2006&2007.My exam is on 12 oct 2008.Its urgent

2051


Explain the advantages and disadvantages of hydropower plant?

1137


Explain dc generator with its types?

1131