what is the highest transmission voltage in India till now?

Answer Posted / rajukumarsripelli

HI
THIS IS RAJKUMAR ....

High voltage transmission will be as follows
110,132,275,400,750kv
in india it must be 750KV MAXIMUM TRANSMISSION VOLTAGE BUT NOT
400KV...THIS IS NOT MY OWN OPENION ITS FROM STANDARD TEXT BOOK

THANKS...

Is This Answer Correct ?    52 Yes 19 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

A Generator is in running condition and Rotor earth fault alarm is coming.How to check on line(i.e in running condition) whether there is actual earth fault in rotor or not.

1436


ho can we calculate the conductor insulation value according to their ratings like voltage,current etc.how insulation value related with voltage,current and power of amachine

1561


there are cam operated switches - why we call cam operated , What is cam ?

1446


why we use copper earthing for neutral while for body GI.

4971


What is the basis for selecting Vk/2 or Vk/4 for REF and Differential protection of Transformer and What is the significance of magnetising current

1885






What is The Resistance Formula

756


What is meant by Im=30mA@Vk/2. How to know the kee point voltage for CT design

2834


What is the function of auadag in a cro?

654


why we are using Load factor?

1338


Explain and give me an example of a time when you had to explain some new procedures to your co-workers for quality service delivery, how did you go about it?

1469


what are the types of electromagnetic forces developed in practical transformer?

2134


following are the questions asked in interviews: 1) Considering the short circuit fault, which switchgear is preferable, SFU OR MCCB? Which operates faster? whicg one is popular in Indian Market and why? 2)Define SCPD. What is type2 coodination? 3)Why the contactor rating is higher for the fuseless selection than for fuse selection? whether the ratinf of SFU or MCCB remains the same in both the cases? 4)If the HP rating is known then can you calculate the ratings of L.V Switchgear(SFU/MCCB, contactor, OLR) without using the selection chart?

1591


what is smart grid? why we use it? explain in detals bcoz i want give presentatin from it....

1456


I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?

1237


What is referred to the electron in the outer orbit?

680