1.Can anybody explain Why starters are not used for motor
starting in industries?
2.
Answer Posted / sennapparajan
oh/...well frnd...u must have seen at any small industries.
they must have used be cos of cost.U can never find in any
standard company.it may happen if its very low rating motor
like up to 0.33kw.
| Is This Answer Correct ? | 1 Yes | 0 No |
Post New Answer View All Answers
WHY SEPARATELY EXCITED MACHINE NEEDS EXCITATION BY DC SUPPLY WHY NOT BY AC
Please explain, how to test vector group of tranformer(Delta y1) . Thank
What will be the impact on motor performance if a LT motor is rewound with changed motor winding data as given below:- Original winding data: total 04 wires = 02 wires of 17 SWG + 02 wires of 16.5 SWG. Changed Winding data: total 03 wires of 15.5 SWG wire size Motor rating: 160KW, 740RPM, 415V, ID FAN application. Normal Running Current = 95% of FL Current.
why asa method ZPF method is more accurate than ASA method?
Define the overload capacity of the motor?
how we arrange the hv side with delta connection in case 33/11kv of transformer.
Brushes are placed at magnetically neutral axis,when brushes reach that point,the armature conductor gets shorted,but it can be seen that the dc supply is also shorted,wont that get damage? help me plz
What should be setting for alarm,tripping and cooling fan on for power transformer's oil temp. and winding temp. indicator?
In Dyn11 power transformer if any one of the 3 phases connected to earth in star connected side then please explain effect of the current flow in delta connected side of transformer.(In this case if one phase is shorted to ground in star connected side then we observe the current flow in two phases only not three phases in delta connected primary side. Please explain why it is so?)
Good day everyone,currently in our premise we using 30kw slip ring motor with resistance bank which we use as forward and reverse at conveyor bar handling. So,my question is how do we calculate the resistance bank which is suit the motor. Kindly,assist me... thank you
if an insulated power and control cables of a running gas diesel gensets laid direct in an open trench i.e, trench bed is not rcc of a power house in which rain water, spillage water alwas exists and all power control cables remains submerged even when gas gensets of 480 kw each runningin on load. These power &control cables runs from power house to switchgear room through these trenches in which water remains most of the time. pl explain its merit & de-merit
why we need to us lenz's law for synchornous motor
upto how much low RPM we will run the commercial motor which is run through VFD without any problem occurs in motor.Motor rating Duty is S1 & RPM is 1400.
what is a types of short circuit and what is a types of distance protection tests
what is the difference between earthing and unearth