What is negative sequence over voltage element?
How to detect voltage vector shifting in interconnection protection.
What is meant by bus bar protection?
lenz law application and define
how to select overload-relay for perticular motor 1.for D.O.L. starter 2. for Star-delta starter ????
how to decide the panel size like MDB ,SMDB PANEL SIZES
Name a govt approved university which have 100% online engineering course.
I am having a 1500 KVA transformer whose secondary current is 2086A and my connected load is 1000 KVA, I am having 400 KVAR APFCR for PF improvement what ratio of CT should i install in LT EB Bus to get optimum PF improvement?
If symmetrical fault occurs at the terminal of a synchronous motor then how the motor will act...explain it..
What is effect on in zone and out zone fault if CT chosen for phase side is Vk/2<5mA and Neutral side is Vk/2<15mA on REF protection of Transformer
What is Phase to Phase clearance for 800V System Operating Voltage as per IEC61439
How good are you in resolving the commercial issues to Employer's advantage?
What is Negative Potential Bias
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
I have a relay contact rated at 220v dc which is supplied with a 24vdc from the panel,for it to trip the dampers(24vdc).What if the application of the relay changes so that it should work at its rated 220vdc then will it work at 24vdc supply given or any other consideration needs to be taken .....